Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 33(5): 1075-1083, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37777044

RESUMO

BACKGROUND: The design of humeral implants has evolved from the initial Grammont design, notably regarding the neck-shaft angle (NSA) and through the use of cementless prostheses. Stress shielding was frequently reported with cementless implants, the 2 main risk factors being humeral stem misalignment and high filling ratios. Our hypothesis was that standard length cementless stems with an NSA of 140° would facilitate good alignment with moderate filling ratios, thereby limiting stress shielding and ensuring good clinical outcomes. METHODS: A single-center retrospective study was conducted of patients who underwent reverse total shoulder arthroplasty between January 2015 and August 2017, with at least 2 years' follow-up. Clinical evaluations included range of motion measurements and Constant and subjective shoulder values scores. Frontal alignment was assessed in terms of the angle (α) between axes of the stem and of the humerus. Filling ratios were measured in the metaphysis of the humerus, in the diaphysis, and at the distal end of the stem and considered excessive above 0.7. Stress shielding was evidenced radiographically by the observation of medial cortical narrowing, medial metaphysis thinning, lateral metaphysis thinning or under-the-baseplate osteolysis. RESULTS: Eighty-two shoulders were included and 70 had radiographic follow-up data available. The mean patient age was 78 years and 63/81 patients (78%) were female. The mean follow-up time was 39 ± 7 months. The mean α angle was 1.4° ± 0.9° and was less than 5° in all cases. The mean metaphyseal, diaphyseal, and distal filling ratios were 0.61 ± 0.06, 0.70 ± 0.08, and 0.64 ± 0.09, respectively. The mean Constant score improved from 28 ± 11 preoperatively to 64 ± 14 at last follow-up. The mean subjective shoulder values score at last follow-up was 81 ± 12. Seventy-nine percent of patients (55/70) had at least 1 form of stress-shielding related, which were not associated with clinical outcomes, apart from lateral metaphysis thinning, which was associated with lower active anterior elevation (mean, 106° ± 30° vs. 126° ± 28°; P = .01) and lower Constant scores (mean, 56 ± 17 vs. 65 ± 14; P = .06). CONCLUSION: The use of cementless reverse shoulder prostheses with a NSA of 140° was associated with good clinical outcomes at 2 years' follow-up. The prosthesis stem was correctly aligned with the humeral axis and the filling ratios were <0.7 in all cases. Stress-shielding was common but, apart from lateral metaphysis thinning, this had no impact on clinical outcomes.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Feminino , Idoso , Masculino , Artroplastia do Ombro/efeitos adversos , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Seguimentos , Resultado do Tratamento , Desenho de Prótese , Prótese de Ombro/efeitos adversos , Úmero/diagnóstico por imagem , Úmero/cirurgia , Amplitude de Movimento Articular
2.
Eur J Trauma Emerg Surg ; 48(6): 4955-4962, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35857068

RESUMO

OBJECTIVE: To evaluate functional results after treatment of large defects of the sciatic nerve and its divisions by direct nerve suturing in high knee flexion. METHODS: A retrospective review was conducted in patients treated for lower extremity nerve defects between 2011 and 2019. Inclusion criteria were a defect > 2 cm with a minimal follow-up period of 2 years for the sciatic nerve and 1 year for its divisions. Nerve defects were bridged by an end-to-end suture with the knee flexed at 90° for 6 weeks. Functional results were assessed based on the Medical Research Council's grading system. RESULTS: Seventeen patients with a mean age of 27.6 years were included. They presented with seven sciatic nerve defects and ten division defects, including eight missile injuries. The mean time to surgery was 12.3 weeks and the mean nerve defect length was 5 cm. Overall, 21 nerve sutures were performed, with eight in the tibial distribution and 13 in the fibular distribution. Post-operatively, there was no significant knee stiffness related to the immobilization. The mean follow-up time was 24.5 months. Meaningful motor and sensory recovery were observed after 7 of 8 sutures in the tibial distribution and 11 of 13 sutures in the fibular distribution. A functional sural triceps muscle with protective sensibility of the sole was restored in all patients. There were no differences according to the injury mechanisms. CONCLUSION: Temporary knee flexion at 90° allows for direct coaptation of sciatic nerve defects up to 8 cm, with promising results no matter the level or mechanism of injury.


Assuntos
Nervo Isquiático , Suturas , Humanos , Adulto , Nervo Isquiático/cirurgia , Nervo Isquiático/lesões , Procedimentos Neurocirúrgicos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...